8.1.2 Touch Panel Data Calibration(CALIB59.EXE)
By touching the specified position (upper left-hand corner or lower right-hand corner)
on the panel, the difference between the screen’s logical value and its measured value is
corrected. Furthermore, it is possible to create files with data based on calibration
results obtained here, to be used with the ATPH59.EXE application (Touch Panel
Handler).
Start-up
CALIB59 [Parameter]
[
↵
]
∗
Parameter
-a<n>
Specifies the I/O base address of the touch panel’s SIO port.
Hexadecimal,
Default: 2e8 (COM4)
n=
3f8
(COM1)
2f8
(COM2)
3e8
(COM3)
2e8
(COM4)
-q<n>
Specifies the interrupt level (IRQ) of the touch panel’s SIO port.
Default: 10
n=
3, 4, 10, 11
-c <path name>
Specifies the data file containing the calibrated value obtained from
the CALIB59.EXE application (touch panel data calibration).
When defaulted to, ATPH59.CAL of the current directory is specified.
∗
Example
CALIB59 -a2e8 -q10 -cc:\atph59.cal
• Normally, only “CALIB59” is needed.
Analog Touch Panel Calibration CALIB59.EXE
Version X.XX
Copyright(c) 2000 Digital Electronics Corporation
Calibration Mode
Touch upper left and lower right cornner of the screen.
[Enter] : Go to test mode.
[Esc] : Terminate program.
Upper left Lower right
(0000,0000) (0000,0000)
1) When the CALIB59.EXE applica-
tion is opened up, the message
shown at the left will appear on
the screen, and two points will
light up, in both the upper left-
hand and lower right-hand cor-
ners.
Operation