Chapter 2 - Specifications
2-3
PL-5910 Series User Manual
2.1.3 Structural
*1 Only PL5910-T11/PL5911-T11 units. (Rated Voltage: 100VAC)
*2 The front face of the PL unit, installed in a solid panel, has been tested using
conditions equivalent to the standard shown in this specification . However even
though the PL unit’s level of resistance is equivalent to the standard, oils that
should have no effect on the PL can possibly harm the unit. This can occur in areas
where either vaporized oils are present, or where low viscosity cutting oils are
allowed to adhere to the face of the unit for long periods of time. If the PL unit’s
front face protection sheet becomes peeled off, these conditions can lead to the
ingress of oil into the PL and separate protection measures are suggested. Also, if
non-approved oils are present, it may cause deformation or corrosion of the front
panel’s plastic cover. Therefore, prior to installing the PL be sure to confirm the
type of conditions that will be present in the PL unit’s operating environment.
• To extend the lifetime of the PL unit's Hard Disk Drive (HDD),
use the BIOS, [POWER MANAGEMENT SETUP]-[HDD Power
Down] setting to stop the HDD motor when the HDD is not be-
ing operated. The factory setting of “5Min” is recommended.
With Windows®2000:
Use the [Control Panel] -> [Power Option] -> [Power Setting] fea-
ture to turn the HDD off when not in use.
(Recommended setting: [After 5 mins]
PL-5910T
PL-5911T
6.0 kg (13.2 lb) or less
5.5 kg (12.1 lb) or less
W 311mm[12.24in.] x
H 271mm[10.67in.] x
D 130mm[5.12in.]
(excluding projections)
W 311mm[12.24in.] x
H 271mm[10.67in.] x
D 93mm[3.66in.]
(excluding projections)
PL-FD500
W 311mm[12.24in.] x
H 271mm[10.67in.] x
D 130mm[5.12in.]
(excluding projections)
W 311mm[12.24in.] x
H 271mm[10.67in.] x
D 123mm[4.84in.]
(excluding projections)
PL-FD510
W 311mm[12.24in.] x
H 271mm[10.67in.] x
D 147mm[5.79in.]
(excluding projections)
W 311mm[12.24in.] x
H 271mm[10.67in.] x
D 145.7mm[5.74in.]
(excluding projections)
W 311mm[12.24in.] x
H 271mm[10.67in.] x
D 152mm[5.98in.]
(excluding projections)
W 311mm[12.24in.] x
H 271mm[10.67in.] x
D 115mm[4.53in.]
(excluding projections)
External Dimensions
Dimensions Including
FDD Unit
Dimensions Including
RS-232C/RS-485
Conversion Unit
Exclusive grounding: Use your country’s applicable standard.
Equivalent to IP65f (JEM 1030)
*2
Natural air ventilation
Grounding
*1
Rating
(Front face of installed unit)
Weight
Cooling Method