![background image](http://html1.mh-extra.com/html/omron/sysmac-c500-nc222-e/sysmac-c500-nc222-e_operation-manual_742438137.webp)
130
9-1
External Display
This section provides only an overview of the External Display. Refer to the
Operation Manual
.
Front Panel
MODE switch
RESET switch
C500-ND201
X
Y
Axis indicator
Indicates X- or Y-axis display during Status mode.
Current address
Displays the current address during Status mode.
M code
Displays M code during Status mode.
Unit/Error LEDs
Override coefficient
Displays override coefficient during Status mode.
Current speed address
Displays current speed address during Status mode.
Multiplier
Displays the multiplier during Status mode.
Current position /Error code
Displays the current position during Current Position mode, and the error code during Error Code mode.
Moving Between
Display Modes
The C500-ND201 External Display has four display modes which can be se-
lected by pressing the MODE and RESET switches.
1, 2, 3...
1.
When power is turned ON the External Display is in Current Position
mode.
2.
Each time you press the mode switch, the display mode advances in the
order Current Position to X-Axis Status to Y-Axis Status and then back
to Current Position. The order circulates in this way no matter what
mode you start in.
3.
In the two Status modes you can press the RESET switch to return im-
mediately to Current Position mode.
4.
The External Display enters the Error Code mode automatically when an
error occurs. When the error clears, the display always returns to Cur-
rent Position mode.
External Display