192
Remote Port Number (Command, Results Storage Area): Specify the
remote TCP port number with this command. If all zeroes are set, no remote
TCP port number is specified. If any other value is set, it specifies the TCP port
number of the remote node. The TCP port number of the connected remote
node will be stored in the results storage area.
Response code
Description
0000
Normal
1100
TCP socket number is out of range.
Remote IP address is 0.
1101
The memory area code for the results storage area is out of
range.
1103
Non-zero bit address is specified for the results storage area.
220F
The specified socket (connection) is already open or is
currently being opened.
Response code
Description
0000
Normal
003E
Cannot secure the internal buffer. (ENOBUFS)
0080
An open request timeout error occurred.
11-3-8 TCP OPEN REQUEST (ACTIVE)
Requests processing to open a TCP socket. The socket will be connected to
another node.
Command Block
11
27
Command
code
Results storage
area
TCP
socket
number
Local
TCP port
number
Remote IP
address
Remote
TCP port
number
Response Block
11
27
Command
code
Response
code
Results Storage Format
Response
code
Local port
number
Parameters
TCP Socket Number (Command): Specify the TCP socket number to be
opened as two bytes between 1 and 4.
Results Storage Area (Command): The words 0 to 255 and 256 to 511 of the
memory area, words 0 to 6143 of the data memory, and words 0 to 6143 (each
bank) of the expansion data memory can be used. However, do not designate
the special auxiliary area. Refer to 11-1-4 Memory Area Designations. When a
bank that does not have expansion data memory is designated, the Results
Storage Area Error Flag will turn ON.
Local TCP Port Number (Command, Results Storage Area): The local TCP
port number is specified as two bytes. An available TCP port number is automat-
ically assigned if 0 is specified. The TCP port number allocated to the open
socket is stored in the results storage area.
Note Do not make other port specifications if you specify the local TCP port number.
Making other specifications may cause transmissions to collide on the port.
Response Codes
Results Storage Area
Response Codes
FINS Commands Requesting Socket Services
Section 11-3
Summary of Contents for SYSMAC C200HW-PCS01-EV1
Page 1: ...Cat No W313 E1 3 PC Card Unit SYSMAC C200HW PCU01 C200HW PCS01 EV1 OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC C200HW PCU01 C200HW PCS01 EV1 PC Card Unit Operation Manual Revised January 2000...
Page 4: ......
Page 6: ......
Page 10: ......
Page 12: ......
Page 18: ......
Page 34: ......
Page 38: ......
Page 60: ......
Page 80: ......
Page 82: ......
Page 88: ......
Page 120: ......
Page 148: ......
Page 178: ......
Page 214: ......
Page 220: ......
Page 232: ......
Page 234: ......
Page 236: ......
Page 238: ......
Page 240: ......