27
Cable Connections
Section 2-4
Note
(1) The cables listed above are black and have power supply lines and ten-
sion members, although the power supply lines aren’t used in the SYS-
MAC LINK Network.
(2) All of the cables listed above are attached to the connectors with adhe-
sive.
(3) Special training is required to assemble Optical Fiber Cables and connec-
tors with adhesive.
Optical Fiber Cable
Accessories
Use the following accessories to assemble and test Optical Fiber Cables.
Note
Use the CAK-0057 (made by Sumitomo Electric Industries, Ltd.) to assemble
the S3200-COCF2071/2571 Connectors. (Production of the S3200-CAK1062
Assembly Tool has been stopped.) The S3200-COCF2071/2571 Connectors
can be assembled using the S3200-CAK1062 by adding the JRFK-57PLUS
(made by Sumitomo Electric Industries, Ltd.).
This manual does not provide details on Optical Fiber Cable preparation. For
details, refer to the instructions provided with the CAK-0057 or S3200-
CAK1062 Assembly Tool.
Optical Fiber Cable Connections
All of the nodes in an Optical SYSMAC LINK Network are connected in a line
(daisy-chain configuration) with H-PCF Optical Fiber Cable.
The nodes can be connected in any order, but be sure to begin with the upper
connector (SL1) of the highest node in the network and connect to the lower
connector (SL2) in the next lower node, as shown in the following diagram.
Optical Fiber Cable Connectors:
S3200-COCF2011
ß
S3200-COCF2511
2 m
S3200-CN201-20-25
5 m
S3200-CN501-20-25
10 m
S3200-CN102-20-25
15 m
S3200-CN152-20-25
20 m
S3200-CN202-20-25
Over 20 m
S3200-CN-20-25
(Specify length (m) when ordering.)
Optical Fiber Cable Connectors:
S3200-COCF2511
ß
S3200-COCF2511
2 m
S3200-CN201-25-25
5 m
S3200-CN501-25-25
10 m
S3200-CN102-25-25
15 m
S3200-CN152-25-25
20 m
S3200-CN202-25-25
Over 20 m
S3200-CN-25-25
(Specify length (m) when ordering.)
Specifications
Length
Model
Name
Model
Specifications
Optical Fiber
Assembly Tool
CAK-0057
(See note.)
Crimp-cut tool for the
S3200-COCF2071/2571 Connectors
Optical Power Tester
S3200-CAT2700
With S3200-CAT2702 Head Unit and
adapter for the S3200-COCF2071/
2571 and S3200-COCF2011/2511
Connectors
Master Fiber Set
S3200-CAT2001H
One meter cable for use with the
S3200-CAT2702 Head Unit
Summary of Contents for CS1W-SLK11-21 - 06-2004
Page 1: ...Cat No W367 E1 02 SYSMAC CS1W SLK11 21 SYSMAC LINK Units...
Page 2: ...CS1W SLK11 21 SYSMAC LINK Units Operation Manual Revised June 2004...
Page 3: ...iv...
Page 5: ...vi...
Page 9: ......
Page 11: ......
Page 17: ......
Page 49: ......
Page 107: ......
Page 139: ...122 FINS Commands for SYSMAC LINK Units Section 6 4...
Page 143: ......
Page 170: ...153 Appendix B Dimensions CS1W SLK11 Optical SYSMAC LINK Unit Unit mm...
Page 171: ...154 Dimensions Appendix B CS1W SLK21 Coaxial SYSMAC LINK Unit Unit mm...
Page 177: ......
Page 179: ......
Page 195: ......
Page 199: ......
Page 202: ...SYSMAC CS1W SLK11 21 SYSMAC LINK Units Cat No W367 E1 02 OPERATION MANUAL...