100
PLC Network Instructions
Section 6-2
6.
Port Number
Set the communications port number that the RECV(98) instruction will be
sent to.
7.
Number of Retries
Set the number of retries for unsuccessful transmissions. You can set the
number between 1 to 15. If 15 has been set, for example, the RECV(98)
instructions will be re-transmitted up to 15 times when the PLC does not
receive a response from the destination node.
8.
Response Monitor Time
Designates the length of time that the PLC retries transmission when bit
15 of C+3 is OFF and no response is received. The default value is $0000,
which indicates 2 seconds.
Range of Control Data
The permissible ranges of control data to be set are as follows:
Item
Value
Number of words
0001 to 0100 (1 to 256 words)
Source network address
0:
Local network
01 to 7F: Source network address
Source node address
00:
Transmission within local PLC
01 to 3E: Source node address (1 to 62) (SYSMAC LINK)
01 to 20: Source node address (1 to 32) (Controller Link)
01 to 7E: Source node address (1 to 126) (Ethernet, SYSMAC NET)
Source unit address
00:
PLC (CPU Unit)
01:
Computer (NSB), user application
10 to 1F: Unit number 0 to 15
E1:
Inner Board
FE:
Unit connected with the network
Response bit
0 (OFF): Required
Communications port number
0 to 7 (0 to 7)
Number of retries
0 to F (0 to 15)
Response monitor time
0000:
2 s (default)
0001 to FFFF: 0.1 to 6,553.5 s in 0.1-s increments (set by the user)
Summary of Contents for CS1W-SLK11-21 - 06-2004
Page 1: ...Cat No W367 E1 02 SYSMAC CS1W SLK11 21 SYSMAC LINK Units...
Page 2: ...CS1W SLK11 21 SYSMAC LINK Units Operation Manual Revised June 2004...
Page 3: ...iv...
Page 5: ...vi...
Page 9: ......
Page 11: ......
Page 17: ......
Page 49: ......
Page 107: ......
Page 139: ...122 FINS Commands for SYSMAC LINK Units Section 6 4...
Page 143: ......
Page 170: ...153 Appendix B Dimensions CS1W SLK11 Optical SYSMAC LINK Unit Unit mm...
Page 171: ...154 Dimensions Appendix B CS1W SLK21 Coaxial SYSMAC LINK Unit Unit mm...
Page 177: ......
Page 179: ......
Page 195: ......
Page 199: ......
Page 202: ...SYSMAC CS1W SLK11 21 SYSMAC LINK Units Cat No W367 E1 02 OPERATION MANUAL...