81
CX-Programmer Procedures
Section 4-12
Starting and Stopping Data Links (with Status Display)
Connect online to a node to which the data link tables have been transferred
before performing the following operations. Data links can be started or
stopped from any node if the node has a data link table.
Starting Data Links
1,2,3...
1.
Start CX-Net and select
Data Link
and then
Status
. If connected locally
(i.e., directly connected to a PLC), the Data Link Status (Local) Dialog Box
will be displayed. If connected remotely (i.e., through a network), the Data
Link Status Dialog Box will appear.
2.
Select
SYSMAC LINK
and then click the
OK
button.
• The Data Link Status Dialog Box will be displayed.
• The status for each of the following will be displayed in the Data Link
Status Dialog Box. The communications cycle time and the refresh cy-
cle time can be updated only when this window is open or when the
data link has been started or stopped.
Edit
Used to edit the data link table that has been read.
Update
Transfers the contents of the file edited in the Data Link Editor to the
Data Link Setup Dialog Box.
Read
Reads the data link table for a specified node.
Write
Transfers data link tables to the nodes.
Verify
Verifies data link tables between nodes and the Data Link Setup
(SYSMAC LINK) Dialog Box.
Delete
Deletes data link tables from the nodes.
Button name
Function
Select this button to display the
Communications Units mounted on
the PLC.
Set the data link start and
stop using this selection
button and then the
Set
op-
tion button.
Summary of Contents for CS1W-SLK11-21 - 06-2004
Page 1: ...Cat No W367 E1 02 SYSMAC CS1W SLK11 21 SYSMAC LINK Units...
Page 2: ...CS1W SLK11 21 SYSMAC LINK Units Operation Manual Revised June 2004...
Page 3: ...iv...
Page 5: ...vi...
Page 9: ......
Page 11: ......
Page 17: ......
Page 49: ......
Page 107: ......
Page 139: ...122 FINS Commands for SYSMAC LINK Units Section 6 4...
Page 143: ......
Page 170: ...153 Appendix B Dimensions CS1W SLK11 Optical SYSMAC LINK Unit Unit mm...
Page 171: ...154 Dimensions Appendix B CS1W SLK21 Coaxial SYSMAC LINK Unit Unit mm...
Page 177: ......
Page 179: ......
Page 195: ......
Page 199: ......
Page 202: ...SYSMAC CS1W SLK11 21 SYSMAC LINK Units Cat No W367 E1 02 OPERATION MANUAL...