161
Appendix E
DM Area Allocations
Words in the DM Area are allocated to CS-series CPU Bus Units according to
the unit numbers assigned to them, as shown below. Each Unit is allocated
100 words, of which 1 word is used.
Software Switches ( 100
×
Unit Number)
Unit No.
Words
Unit No.
Words
0
D30000
8
D30800
1
D30100
9
D30900
2
D30200
10
D31000
3
D30300
11
D31100
4
D30400
12
D31200
5
D30500
13
D31300
6
D30600
14
D31400
7
D30700
15
D31500
Data Link Mode
00:
Manual
01:
Automatic for CIO Area only
10:
Automatic for DM Area only
11:
Automatic for CIO and DM Areas
CPU Bus Unit Settings Initialization
(See note)
0: Do not initialize CPU Bus Unit Settings
1: Initialize CPU Bus Unit Settings
Polling Node/Polled Node Bit
0: Polling node
1: Polled node
Number of Send Words per Node
CIO Area
DM Area
00: 4 words
01: 8 words
10: 16 words
11: 32 words
8 words
16 words
32 words
64 words
Data Link Start Bit
Start: Changed from OFF to ON or already ON when power is turned ON
Stop: Changed from ON to OFF
Note
Initializes the network parameters registered in the CPU Bus Unit Setting Area in the CPU Unit and
clears the data link tables.
Summary of Contents for CS1W-SLK11-21 - 06-2004
Page 1: ...Cat No W367 E1 02 SYSMAC CS1W SLK11 21 SYSMAC LINK Units...
Page 2: ...CS1W SLK11 21 SYSMAC LINK Units Operation Manual Revised June 2004...
Page 3: ...iv...
Page 5: ...vi...
Page 9: ......
Page 11: ......
Page 17: ......
Page 49: ......
Page 107: ......
Page 139: ...122 FINS Commands for SYSMAC LINK Units Section 6 4...
Page 143: ......
Page 170: ...153 Appendix B Dimensions CS1W SLK11 Optical SYSMAC LINK Unit Unit mm...
Page 171: ...154 Dimensions Appendix B CS1W SLK21 Coaxial SYSMAC LINK Unit Unit mm...
Page 177: ......
Page 179: ......
Page 195: ......
Page 199: ......
Page 202: ...SYSMAC CS1W SLK11 21 SYSMAC LINK Units Cat No W367 E1 02 OPERATION MANUAL...