7-74 Installing replaceable parts
a) Disconnect the security PCP cable (J31) from the
rear terminal PCP connector (J32).
b) If the terminal has an IAS module, disconnect the
interconnect cable between the IAS module and the
rear terminal PCP.
3.
Refer to Figure 7-61 and remove the rear terminal PCP
retaining screw, in the middle of the rear terminal PCP.
4.
Remove the rear terminal PCP from its terminal mount.
:igure 7-61: Close-up of rear terminal PCP and rain diverter
Rear terminal housing
Rear terminal
rain diverter
slides behind
rear terminal
mount
Rear terminal
mount
5. To replace the rear terminal PCP reverse Steps 1 to 3.
• When inserting the new rear terminal PCP, make
sure the alignment pins on the terminal mount fit
into the holes in the housing assembly.
•
If you are installing a rear terminal rain diverter,
follow the procedure described below before tight
ening the central screw on the rear terminal PCP.