Installing replaceable parts 7-91
Connect the J38 end of the keypad two-wire cable to
connector J36 on the smart card alert daughter board.
Refer to Figure 7-74 for daughter board connectors.
Figure 7-74: Connectors on the sm art card alert board
J26
J37
o o o o o o o o o o o o
o o o o o o o o o o o o
4-pin connector
for keypad link
_ 3-pin connector
for alerter link
24-pin connector
■ (below board)
inserts into
U25 socket
4. Make sure all the connectors are properly seated.
5.
Reconnect the power, close and lock the terminal, and
put the terminal back in service by following the steps in
Opening the terminal.
6.
Re-INSTALL the terminal with the
INSTALL terminal-
configuration routine
described in Chapter 3.
Note:
This step is not necessary if you replaced a smart
card alert daughter board.
7. Test the alarm:
a) Take the handset off-hook.
b) Insert a smart card with a value greater than zero
into the card reader.
c) Place the handset back on hook.
d) When the alarm sounds, remove the smart card.
Millennium multi-pay terminal installation, operation, and maintenance guide
Summary of Contents for Millennium multi-pay M1211
Page 3: ...iv NTP 506 6501 203 Document issue 00 01 Status Standard Date January 1997...
Page 17: ...xviii Table of contents NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Page 21: ...t ATG 4 About this guide I NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Page 283: ...Customer orderable parts 9 11 Figure 9 4 Auxiliary view multi pay terminal chassis...
Page 304: ...A 16 Appendix A List of alarms NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Page 349: ......