7-2 Installing replaceable parts
• coin box rail
• vault security PCP
• coin compartment lock, mechanical or electronic
• coin box and coin box cover
• escrow
• rear terminal PCP
• IAS (inferred answer supervision) module (optional)
• data jack connector (optional)
• smart card alert daughter board (optional)
Table 9-2 in Chapter 9 contains a complete list of orderable
modules for the terminal.
Saving call detail records (CDRs)
It is important to upload all CDRs from the terminal before
performing maintenance tasks inside the terminal. Although
records may not be directly affected by what you are doing,
uploading the CDRs assures that the terminal records are
up-to-date as of the time of maintenance, should something
prevent the terminal from regaining operation.
During this procedure, the cash box record is also uploaded,
to ensure a current cash box status is maintained should a
terminal failure occur.
Before you enter the terminal
To access the inside of the terminal you require mainte
nance-level privileges, an upper housing key, and a locking
tool (T- or L-tool) to access the terminal.
You may need to access the terminal if the terminal is out of
service or if you have run the craft interface tests and
discovered a faulty component.
• If you know you will be replacing the control PCP or firm
ware on it, you need to uninstall the terminal before you
NTP: 506-6501-203 Document issue: 00.01 Status: Standard Date: January 1997
Summary of Contents for Millennium multi-pay M1211
Page 3: ...iv NTP 506 6501 203 Document issue 00 01 Status Standard Date January 1997...
Page 17: ...xviii Table of contents NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Page 21: ...t ATG 4 About this guide I NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Page 283: ...Customer orderable parts 9 11 Figure 9 4 Auxiliary view multi pay terminal chassis...
Page 304: ...A 16 Appendix A List of alarms NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Page 349: ......