7-64 Installing replaceable parts
6. To replace the security PCP, reverse the preceding
steps, including connecting the module cable (J31) to
the connector on the rear terminal PCP (J30).
7. When complete, reconnect the upper terminal block
onto the rear terminal PCP to reconnect the power and
close and lock the housing assembly. R eferto
Opening
the terminal,
if necessary.
8.
Simulate a coin collection in order to reset the counter
in the terminal. To do this, follow these steps:
Sim ulating a
coin collection
a) Turn the coin box key to the locked position.
b) Push in the coin box microswitch with your left
hand, or use a lid-less coin box. Do not use a new
coin box for this purpose). Refer to Figure 7-53
c) Open the terminal and reconnect the power.
d) Close the terminal and lock it.
e) Turn the lower housing key to the open position.
f) Release the microswitch, or remove the lid-less
coin box. The terminal will see this as a legitimate
collection and reset its coin box status to zero.
g) Insert a new coin box and close the vault as
explained in
Replacing the vault door or the
coin box.
Note:
Be sure to follow procedure for notifying the
coin collection service that maintenance took place
involving removing the coin box.
NTP: 506-6501-203 Document issue: 00.01 Status: Standard Date: January 1997
Summary of Contents for Millennium multi-pay M1211
Page 3: ...iv NTP 506 6501 203 Document issue 00 01 Status Standard Date January 1997...
Page 17: ...xviii Table of contents NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Page 21: ...t ATG 4 About this guide I NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Page 283: ...Customer orderable parts 9 11 Figure 9 4 Auxiliary view multi pay terminal chassis...
Page 304: ...A 16 Appendix A List of alarms NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Page 349: ......