6-6 Troubleshooting strategies
Figure 6-2: Validator jam (Error 67 on craft interface)
Replace validator
Remove validator unit
I __________
Remove reject chute
from validator
Remove upper and lower
runways by sliding short and
long locking pins up
'
T " '
:
Clear jam. Wipe runways
Reassemble and ensure that
actuator and latch are
positioned properly
Run INSTALL
routine
Disconnect power