Appendix B: Error codes
B-3
Table B-1: Craft interface error code descriptions (continued)
2 1
Encountered during:
Call to the Millennium Manager.
Description:
Indicates no dial tone.
Usually occurs during the call setup table download.
Action:
Check for dial tone. Refer to troubleshooting descrip
tions in Chapter 6.
2 2
Encountered during:
Call to the Millennium Manager.
Description:
Indicates the destination Millennium Manager or
modem pool is busy.
Usually occurs during the call set-up when obtaining
a table download.
Action
1.
Try calling again. If, after several attempts, the
problem persists, call the Millennium Manager di
rectly and listen for a modem tone. Once the mo
dem tone is heard, retry the table download.
2.
If the download is still unsuccessful, replace the
control PCP.
3.
If the modem tone cannot be heard, the problem
is not in the terminal. Contact the Millennium
Manager system administrator to confirm that the
system and modems are operating properly.
23
Encountered during:
Call to the Millennium Manager.
Description:
Indicates the carrier was lost.
• Usually occurs during the call set-up when obtaining
a table download.
• The terminal was connected to the Millennium
Manager, but the Millennium Manager dropped the
carrier.
Action continues on the next page
Millennium multi-pay terminal installation, operation, and maintenance guide
Summary of Contents for Millennium multi-pay M1211
Page 3: ...iv NTP 506 6501 203 Document issue 00 01 Status Standard Date January 1997...
Page 17: ...xviii Table of contents NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Page 21: ...t ATG 4 About this guide I NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Page 283: ...Customer orderable parts 9 11 Figure 9 4 Auxiliary view multi pay terminal chassis...
Page 304: ...A 16 Appendix A List of alarms NTP 506 6501 203 Issue 00 01 Status Standard Date January 1997...
Page 349: ......