2.3
Specifications
2.3.1 Transmitter
Power supply
100 to 240 V AC, +10 % / -15 %, 47 to 63 Hz
or 24 V DC ±15 %, 5 % residual fluctuation
Power consumption
max. 48 VA
Wall mount enclosure
-
Material:
Polycarbonate
-
Weight:
approx.
ca. 3700 g
-
Protection:
IP 65
Operating temperature
-20 °C to +50 °C
Storage temperature
-30 °C to +70 °C
Max. humidity
80 %, non-condensing
Display
Back-lit graphic display, 128 x 128 pixel
Operation
18 keys, dialog mode in German, English, French, Italian, Spanish, Polish,
Czech and Dutch
Outputs
-
load 500 Ohm, 12 bit resolution, accuracy better than 0.1 %
-
5 switchable relays, loadable up to 230 V AC / 2 A (cos.
ϕ
0,9
)
-
RJ45 for Internet communication
Data storage
plug-in compact flash card up to 128 MB
Data transmission
Via Compact Flash Card, Modbus TCP, integrated web server; connection
to local networks (LAN) and Wide Area Network (WAN, Internet)
via Ethernet or optional internal ISDN/GPRS or analog modem
2.3.2 Clamp On System
Measurement principle
Ultrasonic transit time as clamp on system
Material
PEEK and stainless steel 1.4571
Measurement frequency
1 MHz; other frequencies upon request
Velocity range
±
20 m/s
Inner pipe diameter
0,08 m to 1,4 m (DN 80 to DN1400)
Protection
IP 68
Operating temperature
-30 °C to +80 °C (ambient temperature)
Storage temperature
-30 °C bis +70 °C
Cable length
10 m
Type of cable
Twinax
Outside cable diameter
8,5 mm
Sensor types
Pair of sensors to clamp on pipes
Measurement uncertainty
Depending on hydraulic
conditions
-
Flow velocity (v
average
) within path ±0.1 % of measurement value
-
Flow (Q): ±1-5 % of measurement value
-
Offset velocity < ±5 mm/s
Temperature measurement using velocity of sound
Measurement range within
medium
0 °C to +80 °C
Measurement uncertainty
± 1 K