Instruction manual
NivuSonic Clamp on
1 Sensor
1
2 Sensor
2
Fig. 6-5
1 path measuring, path arrangement: v echo
1 Sensor
1
2 Sensor
2
Fig. 6-6
1 path measuring, path arrangement: diagonal
To avoid disturbances from electrical interferences, the sensor cable must not
be laid close or parallel to engine (motor) lines or main power lines.
Accurate sensor adjustment is very important. You can check it here in the menu
item I/O-sensors-LDV signal strength (see Fig. 8-65). Readjust the sensor
alignment on one sensor only. After reaching the highest possible signal
strength fix the sensors by tightening the turnbuckles.
The minimum bending radius of the standard signal cable is 10 cm (3.94 in.)
Smaller radii may result in cable break and, in case of using sensors with inte-
grated air hose, kinked and blocked compensation lines (faulty or failed level
measurement)!
Page 24