Instruction manual
NivuSonic Clamp on
α
≤
15° L
≥
min. 3x DN L
≥
min. 5x DN
α
≤
45° L
≥
min. 5x DN L
≥
min. 10x DN
α
≤
90° L
≥
min. 10x DN L
≥
min. 15-20x DN
Fig. 6-8
Sensor position behind curves or elbows
h
≤
5% von DN
L
≥
min. 3x DN
h
>
5% von DN
L
≥
min. 5x DN
h
≥
30% von DN
L
≥
min. 10x DN
Fig. 6-9
Sensor position after change of profile