Instruction manual
NivuSonic Clamp on
®
Fig. 8-64
Velocity screen
Missing velocities indicate that e.g. there is no more water in the measurement
path which interrupts signal transmission between the sensors. Please also
check additionally if the sensors have been connected correctly.
LDV signal strength
This submenu indicates the signal strength of the transmission between both
sensors. Range: 0 to 60 dbmV
Fig. 8-65
Signal strength screen
This menu allows to check how the sensors are adjusted to each other and to
improve the respective alignment if required. To obtain proper results the signal
strength should be between 30 and 55 dbmV.
8.6.4 I/O Menu "Interfaces"
The menu includes the transmission speed of the internal interfaces. It has no
meaning for users and is going to be used for service purposes only.
8.6.5 I/O Menu "Memory Card"
This menu enables to view various information regarding the memory card. Ad-
ditionally it is possible to save data as well as to read out and to load the pa-
rameters set.
Fig. 8-66
Memory card menu
Info
Information on the remaining card capacity and the remaining storage time is
available here.
NivuSonic CO - Rev. 00 as of 08.12.2010
Page 79
Summary of Contents for NivuSonic Clamp On
Page 109: ...18 Declaration of Conformity...
Page 110: ......