Quick Start Guide
Laser sensor with dual outputs and IO-Link
This guide is designed to help you set up and install the Q5X Laser Measurement Sensor. For complete information on
programming, performance, troubleshooting, dimensions, and accessories, please refer to the Instruction Manual at
. Search for p/n 208794 to view the Instruction Manual. Use of this document assumes familiarity with
pertinent industry standards and practices.
WARNING:
•
Do not use this device for personnel protection
•
Using this device for personnel protection could result in serious injury or death.
•
This device does not include the self-checking redundant circuitry necessary to allow its use in
personnel safety applications. A device failure or malfunction can cause either an energized (on) or de-
energized (off) output condition.
Features
The Q5X has three major features.
Figure 1. Q5X Features
1
2
3
1. Two output indicators (amber)
2. Display
3. Buttons
Display and Indicators
The display is a 4-digit, 7-segment LED. Run mode is the primary view displayed.
For 2-pt, BGS, FGS, and DYN TEACH modes, the display shows the current distance to the target in centimeters. For Dual TEACH
mode, the display shows the percentage matched to the taught reference surface. A display value of
indicates the sensor
has not been taught.
Figure 2. Display in Run Mode
STB DYN FGS BGS
1
2
1. Stability Indicator (STB—Green)
2. Active TEACH Indicators
•
DYN—Dynamic (Amber)
•
FGS—Foreground Suppression (Amber)
•
BGS—Background Suppression (Amber)
Output Indicator
•
On—Output is on
•
Off—Output is off
Stability Indicator (STB)
•
On—Stable signal within the specified sensing range
•
Flashing—Marginal signal (low excess gain), the target
is outside the limits of the specified sensing range, or a
multiple peak condition exists
•
Off—No target detected within the specified sensing
range
Active TEACH Indicators (DYN, FGS, and BGS)
•
DYN, FGS, and BGS all off—Two-point TEACH mode
selected (default)
•
DYN on—Dynamic TEACH mode selected
•
FGS on—Foreground suppression TEACH mode
selected
•
BGS on—Background suppression TEACH mode
selected
•
DYN, FGS, and BGS all on—Dual TEACH mode
selected
Q5X Laser Measurement Sensor with Dual
Discrete Outputs and IO-Link
Original Document
208795 Rev. G
10 January 2023
208795