Figure 20. Sensor Menu Map—Channel 2
Two-Point Static Teach
Dynamic Teach
Background Suppression
Foreground Suppression
Top Menu
Sub Menu
off: no delays enabled
on: enable on and/or off delay (set value in Delay Timer menu)
1 Shot, fixed output pulse duration
Total
end: exit setup
Teach Selection CH2
Output CH2
Window Size CH2 **
Output Timing Delays CH2
Offset CH2 ****
Exit Setup
default setting
Light Operate
Dark Operate
Complimentary to Output 1
Dual Mode
Adaptive Tracking CH2 *
off: Adaptive Tracking off
High-Speed Adaptive Tracking on
on: Adaptive Tracking on
Channel 2
Adaptive Tracking menu is available when Teach CH2 is set to Dual Mode
laser off when pulled high
laser on when pulled high
set: Remote Teach input
master
slave
pulse
0 ms to 90.0 sec range, set Delay Timer value (seconds have decimal)
Menu not present when dLY2 is set to off
(ond2 and oFd2 defaults to 0, dt2 defaults to 10)
Delay Timer CH2 ***
Available when
set to
Available when
set to
available when
set to
or
Menu items only available when
out2 is set to LO or DO
=
Auto
Set Value:
Offset menu is available when Teach CH2 is set to FGS or BGS
-191 to 191 cm (2000 mm models); -497 to 497 cm (5000 mm models);
-997 to 997 cm (10000 mm models)
0.1 to 191 cm (2000 mm models); 2 to 497 cm (5000 mm models);
2 to 997 cm (10000 mm models)
Window Size menu is available when Teach CH2 is set to FGS
Set to 0.1 to 200 cm (2000 mm models); 0.1 to 500 cm (5000 mm models);
0.1 to 1000 cm (10000 mm models)
Sensor controls hysteresis dependent on distance value
Set to -0.1 to -200 cm (2000 mm models); -0.1 to -500 cm (5000 mm models);
-0.1 to 1000 cm (10000 mm models)
Hysteresis CH2
dt1 range: 1 ms to 90 s or 10 ms to 90 s, depending on response speed setting
Hysteresis menu is available when Teach CH2 is set to Two-Point Static, Dynamic, or BGS
Q5X Laser Measurement Sensor with Dual Discrete Outputs and IO-Link
8
www.bannerengineering.com - Tel: + 1 888 373 6767
P/N 208795 Rev. G