Note:
The number that follows a menu option, for example
, indicates the channel that is selected. For
menu items without a number (excluding submenu items), these menu options are only available from Channel 1
and the settings apply to both channels.
Figure 19. Sensor Menu Map—Channel 1
no: do not reset to factory defaults
yes: reset to factory defaults
Two-Point Static Teach
Dynamic Teach
Background Suppression
Foreground Suppression
Top Menu
Sub Menu
off: no delays enabled
on: enable on and/or off delay (set value in Delay Timer menu)
1 Shot, fixed output pulse duration
Totalizer
0 ms to 90.0 sec range, set Delay Timer value (seconds have decimal)
display on
display on, inverted
display off (enters sleep mode after 60 seconds)
display off, inverted (enters sleep mode after 60 seconds)
end: exit setup
Teach Selection CH1
Output CH1
Window Size CH1 **
Response Speed CH1 & CH2
Output Timing Delays CH1
Delay Timer CH1 ***
Offset CH1 ****
Display Read CH1 & CH2
Exit Setup
Reset to Factory Defaults CH1 & CH2
Available when
set to
Available when
set to
default setting
Light Operate
Dark Operate
Dual Mode
0.1 cm to 191 cm for 2000 mm models
2 cm to 497 cm for 5000 mm models
Auto
Adaptive Tracking CH1 *
Menu not present when dLY1 is set to off
(ond1 and ofd1 default to 0, dt1 defaults to 10)
Set Value:
off: Adaptive Tracking off
High-Speed Adaptive Tracking on
on: Adaptive Tracking on
Channel 1
Window Size menu is available when Teach CH1 is set to FGS
Adaptive Tracking menu is available when Teach CH1 is set to Dual Mode
Gain and Sensitivity CH1 & CH2
near: set zero displayed value to the housing face
far: set zero displayed value to maximum detection range
Select Zero Reference Location CH1 & CH2
on: move the zero point after each teach
off: zero point is either at the housing face or maximum
detection range
Shift Zero Reference after Teach CH1 & CH2
available when
set to
or
Offset menu is available when Teach CH1 is set to FGS or BGS
2000 mm
-191 cm to 191 cm for 2000 mm models
-497 cm to 497 cm for the 5000 mm models
0.1 to 200 cm (2000 mm); 0.1 to 500 cm (5000 mm);
Sensor controls hysteresis dependent on distance value
-0.1 to -200 cm (2000 mm); -0.1 to -500 cm (5000 mm);
-0.1 to 1000 cm (10000 mm)
Hysteresis CH1
centimeter (with decimal point at < 60 cm)
inch (with decimal point at < 24 inches)
Distance Unit CH1 & CH2
IO-Link on Pin 4, PNP on Pin 2
Fixed PNP on Pins 2, 4
Output Type Polarity
Fixed NPN on Pins 2, 4
dt1 Range: 1 ms to 90 s or 10 ms to 90 s,
depending on response speed setting
Hysteresis menu is available when Teach CH1
is set to Two-Point Static, Dynamic, or BGS
Response Speeds (ms)
5000 and 10000 mm
2000 mm 5000 and 10000 mm
millimeter (only available in 5000 and 10000 mm models)
2 cm to 997 cm for 10000 mm models
-997 cm to 997 cm for the 10000 mm models
0.1 to 1000 cm (10000 mm)
Q5X Laser Measurement Sensor with Dual Discrete Outputs and IO-Link
P/N 208795 Rev. G
www.bannerengineering.com - Tel: + 1 888 373 6767
7