background image

Class 2 Red Laser models with maximum range > 2000 mm: Reference IEC 60825-1:2014

Figure 5. FDA (CDRH) warning label (Class 2)

LASER LIGHT 

DO NOT STARE INTO BEAM 

CLASS 2 LASER PRODUCT

IEC 60825-1:2014. Wavelength 

640-670nm; 1.0mW max. Complies with 

21 CFR 1040.10 and 1040.11 except for

conformance with IEC 60825-1: 2014

as described in Laser Notice

 No. 56, dated May 8, 2019.

Output:

 < 1.0 mW

Laser wavelength:

 640 to 670 nm

Pulse Duration for <5 m Models:

 20 µs to 2 ms

Pulse Duration for ≥ 5 m Models:

 3 µs

Installation

Sensor Orientation for the Triangulation Models

Optimize detection reliability and minimum object separation performance with correct sensor-to-target orientation.
To ensure reliable detection, orient the sensor as shown in relation to the target to be detected.

Figure 6. Optimal Orientation of Target to Sensor

See the following figures for examples of correct and incorrect sensor-to-target orientation as certain placements may pose

problems for sensing some targets. The Q5X can be used in the less preferred orientation and at steep angles of incidence and still

provide reliable detection performance due to its high excess gain. For the minimum object separation distance required for each

case, refer to .

Figure 7. Orientation by a wall

Incorrect

Correct

CC

Figure 8. Orientation for a moving object

CC

Incorrect

Correct

Figure 9. Orientation for a height difference

CC

Incorrect

Correct

Figure 10. Orientation for a color or luster difference

Horizontal 

Orientation

Vertical 

Orientation

(Optimal)

CC

Figure 11. Orientation for highly reflective target

1

Reflective

Surface 

(optional)

Mount the Device

1. If a bracket is needed, mount the device onto the bracket.
2. Mount the device (or the device and the bracket) to the machine or equipment at the desired location. Do not tighten the

mounting screws at this time.

1

Applying tilt to sensor may improve performance on reflective targets. The direction and magnitude of the tilt depends on the application, but a 15° tilt is often sufficient.

Q5X Laser Measurement Sensor with Dual Discrete Outputs and IO-Link

 

 

P/N 208795 Rev. G

www.bannerengineering.com - Tel: + 1 888 373 6767

3

Summary of Contents for Q5X

Page 1: ...is the primary view displayed For 2 pt BGS FGS and DYN TEACH modes the display shows the current distance to the target in centimeters For Dual TEACH mode the display shows the percentage matched to t...

Page 2: ...target For Safe Laser Use Class 2 Lasers Do not stare at the laser Do not point the laser at a person s eye Mount open laser beam paths either above or below eye level where practical Terminate the b...

Page 3: ...e targets The Q5X can be used in the less preferred orientation and at steep angles of incidence and still provide reliable detection performance due to its high excess gain For the minimum object sep...

Page 4: ...2 10 30 V DC CH1 CH2 Load Load PNP Discrete Outputs Figure 15 Channel 1 PNP Output Channel 2 PNP Output bk 4 bn 1 bu 3 wh 2 10 30 V DC CH1 CH2 Load Load NPN Output and Remote Input Figure 16 Channel 1...

Page 5: ...emale Straight Male Straight Male 1 4 5 3 2 1 Brown 2 Not Used 3 Blue 4 Black 5 White MQDC 4506SS 1 83 m 6 00 ft M12 X 1 0 43 5 0 5 L1 5 9 M12 X 1 0 14 5 14 5 40 0 5 Female 2 3 4 1 1 Brown 2 White 3 B...

Page 6: ...r sensor Table 1 Button association between the RSD1 and the Q4X Q5X sensors Device Up Button Down Button Enter Button Escape Button RSD1 Q4X and Q5X N A Sensor Programming Program the sensor using th...

Page 7: ...Tracking on Channel 1 Window Size menu is available when Teach CH1 is set to FGS Adaptive Tracking menu is available when Teach CH1 is set to Dual Mode Gain and Sensitivity CH1 CH2 near set zero disp...

Page 8: ...d oFd2 defaults to 0 dt2 defaults to 10 Delay Timer CH2 Available when set to Available when set to available when set to or Menu items only available when out2 is set to LO or DO Auto Set Value Offse...

Page 9: ...ived distance or amount of returned light Manual Adjustments Manually adjust the sensor switch point using the and buttons 1 From Run mode press either or one time The selected channel displays briefl...

Page 10: ...e 2 5 15 50 or 250 ms Delay at Power Up 2 5 s Maximum Torque Side mounting 1 N m 9 in lbs Ambient Light Immunity 2000 mm model 5000 lux at 1 m 2000 lux at 2 m 5000 and 10000 mm models 5000 lux Tempera...

Page 11: ...mode is approximately three times higher than in performance gain mode It is useful for low reflectivity targets Excess gain in shiny gain mode is approximately one third the excess gain of performanc...

Page 12: ...ordance with local and national electrical codes and regulations Overcurrent protection is required to be provided by end product application per the supplied table Overcurrent protection may be provi...

Page 13: ...t Separation Repeatability Figure 23 Minimum Object Separation for 50 ms Response Time Target to Background mm Dimension Y 0 0 Distance to Target mm Dimension X Minimum Object Separation 1000 2000 300...

Page 14: ...ng Corp will repair or replace free of charge any product of its manufacture which at the time it is returned to the factory is found to have been defective during the warranty period This warranty do...