background image

 

1

INSTRUCTION MANUAL

CAUTION: Read All Instructions Before Operating Equipment

MFJ ENTERPRISES, INC.

300 Industrial Park Road

 Starkville, MS 39759  USA

Tel: 662-323-5869 Fax: 662-323-6551

COPYRIGHT         2016  MFJ  ENTERPRISES,  INC.

Model MFJ-200A

VERSION 1A

Inductance/Capacitance Meter

 

Summary of Contents for MFJ-200A

Page 1: ...All Instructions Before Operating Equipment MFJ ENTERPRISES INC 300 Industrial Park Road Starkville MS 39759 USA Tel 662 323 5869 Fax 662 323 6551 COPYRIGHT 2016 MFJ ENTERPRISES INC Model MFJ 200A VERSION 1A Inductance Capacitance Meter ...

Page 2: ...e think you ll like Multiple Ranges Four selectable ranges 0 01pF 10uF 1uF 100uF 0 001uH 100mH 001mH 100H Computation High speed Microcontroller precision computation Power Use four AA batteries not included 5 5mm DC AC adapter or any USB source with a mini USB plug Sleep Mode Intellectually shutdown in 5 min Just push power switch to resume testing Important Warnings Do not reset to 0 as componen...

Page 3: ... calculate capacitance ranges 01pF 10uF Push button Hi L switch 3 allows the user to calculate inductance ranges o Button pushed out calculate inductance ranges 100mH 100H o Button pushed in calculate inductance ranges 001 100mH Push button L C switch 4 allows the user to select inductance or capacitance o Button pushed out capacitance C o Button pushed in inductor L Push button Func switch 5 allo...

Page 4: ...lts for capacitance and Induction Test Leads o Positive 7 o Negative 8 Power Supply o On Off Switch 9 Up position is on Down position is off o Mini USB Interface 10 o 5 5mm DC socket 11 o 4 AA batteries 12 not included Figure 2 MFJ 200A INDUCTANCE CAPACITANCE METER Left Side Panel 9 10 ...

Page 5: ...5 Figure 3 MFJ 200A INDUCTANCE CAPACITANCE METER Right Side Panel Figure 4 MFJ 200A INDUCTANCE CAPACITANCE METER Back Side Panel 11 12 ...

Page 6: ...OVER RANGE Hi C Button in LCD screen will display 00uF When testing lead open loop in capacitance or Inductance and MFJ 200A does not measure 0 when testing lead short circuit Rest to 0 by way of capacitance model or inductance model Capacitance model Press Zero button as testing lead open loop it displays CALCULATING keep pressing for one second when CALCULATING OK displayed resetting to 0 is fin...

Page 7: ...Capacitance Resolution 01uF Hi L Button in Accuracy 5 Range 001uH 1uH 1 Range 1uH 100mH Minimum Inductance Resolution L Range is 001uH Hi L Button out Accuracy 1 Range 100mH 1H 5 Range 1H 100H Minimum Big Inductance Resolution 001Mh Power 5 5 DC Socket on right side Mini USB plug on left side AC DC Switch on left side 4 AA Batteries not included Range Four measuring positions 1 C range Capacitance...

Page 8: ...ng to 0 is needed 2 At the time of resetting to 0 when CALCULATING OK appeared please keep pressing for 2 to 3 seconds and the parameter written to will be prompted then release 3 The time of measuring a big capacitance above 10mF may be more than one second and it needs seven to eight seconds to get the measured value of the capacitance 100mF ...

Page 9: ...ervice Department at 662 323 0549 or the MFJ Factory at 662 323 5869 4 This warranty does not apply to kits sold by or manufactured by MFJ Enterprises Inc 5 Wired and tested PC board products are covered by this warranty provided only the wired and tested PC board product is returned Wired and tested PC boards installed in the owner s cabinet or connected to switches jacks or cables etc sent to MF...