Electra Elite IPK II
Document Revision 1
Warning Tone For Long Conversation
2 - 965
25-07-07 : System Timers for VRS/DISA - DISA Conversation Warning Tone Time
Determine the length of time the system should wait before the Warning Tone is heard by DISA
callers (0-64800 seconds). If an outside call is transferred or forwarded off-premise using an
outside trunk, this timer starts immediately. This will occur if either trunk involved in the call is
programmed for the Warning Tone (Program 14-01-17).
25-07-08
System Timers for VRS/DISA - DISA Long Conversation Disconnect
Determine how long after the Warning Tone is heard the system will wait before disconnecting
DISA calls - unless the Continue code is entered (Program 25-13-02).
Related Features
Central Office Calls, Answering
Central Office Calls, Placing
Direct Inward System Access (DISA)
Intercom
Long Conversation Cutoff
Single Line Telephones, Analog 500/2500 Sets
Toll Restriction
Operation
Warning Tone for Long Conversation is automatic if programmed.
Warning Tone for Long Conversation for DISA Callers:
1.
A DISA caller dials into the system and places a call.
2.
Once the Warning Tone is heard, “To continue the call”, the DISA caller presses the
programmed Continue Code.
- OR -
To disconnect the call, the DISA caller presses the programmed Disconnect Code.
Summary of Contents for ELECTRA ELITE IPK II
Page 2: ......
Page 3: ...FEATURES AND SPECIFICATIONS MANUAL INT 1072 IPK II DOCUMENT REVISION 1 RELEASE 1000 ...
Page 4: ......
Page 6: ......
Page 50: ...Document Revision 1 Electra Elite IPK II 2 28 Alarm THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 104: ...Document Revision 1 Electra Elite IPK II 2 82 Barge In THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 166: ...Document Revision 1 Electra Elite IPK II 2 144 Callback THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 254: ...Document Revision 1 Electra Elite IPK II 2 232 Conference THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 366: ...Document Revision 1 Electra Elite IPK II 2 344 Door Box THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 370: ...Document Revision 1 Electra Elite IPK II 2 348 Drop Key THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 428: ...Document Revision 1 Electra Elite IPK II 2 406 Flash THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 470: ...Document Revision 1 Electra Elite IPK II 2 448 Hotel Motel THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 482: ...Document Revision 1 Electra Elite IPK II 2 460 Intercom THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 574: ...Document Revision 1 Electra Elite IPK II 2 552 K CCIS T1 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 600: ...Document Revision 1 Electra Elite IPK II 2 578 Memo Dial THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 776: ...Document Revision 1 Electra Elite IPK II 2 754 SLT Adapter THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 872: ...Document Revision 1 Electra Elite IPK II 2 850 Transfer THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 995: ......
Page 996: ...FEATURES AND SPECIFICATIONS MANUAL NEC Unified Solutions Inc Document Revision 1 ...