Document Revision 1
Electra Elite IPK II
2 - 534
ISDN Compatibility
B
Is the amount of time the system waits before
placing the call in a talk state sufficient?
In 21-01-03, enter
the interval for the
trunk interdigit timer.
Should extension users
have one-button placing
of outside calls?
Should extension users have
one-button access to trunk
groups for placing calls?
In 15-07-01, do not assign
function keys as line keys.
In 15-07-01, assign
function keys as line
keys (code *01+001- 200).
In 15-07-01, assign CAP Keys
(*08) or line group keys (*02).
In 15-07-01, do not
assign Trunk Group
Access or trunk group keys.
Do you want to adjust
the gain (volume) for
trunks?
Adjust the CODEC Gain
in 14-01-02 (transmit)
and 14-01-03 (receive).
Check the Analog Trunk Timers in 81-01
for compatibility with the telco.
If desired, assign names to
trunks in 14-01-01.
Do you want to set up
an Alternate Trunk
Route Access Code ?
Stop
In 11-01-01, set up a
Service Code for
Alternate Trunk Route
Access.
No
Yes
No
Yes
Yes
No
See "CAP Key" in the
Feature & Specification
manual for more details.
Trunks
No
Yes
No
For example, to make
50 the Alternate Trunk
Route Access Code:
DIAL = 5
Digit = 2
Kind = 8
In 11-09-02, assign the
Service Code set up in the
previous step for Alternate
Trunk Route Access.
Should extension be
able to use Alternate
Trunk Route Access?
In 21-15-01, enter the
extension number and
enter the Trunk Group
Routing route number.
In 21-15-01, enter the
extension number
and enter 0 to
prevent routing.
No
Yes
Is Trunk Group
Routing defined?
Refer to the Trunk
Group Routing
feature and set up
Trunk Group
Routing.
Stop
Summary of Contents for ELECTRA ELITE IPK II
Page 2: ......
Page 3: ...FEATURES AND SPECIFICATIONS MANUAL INT 1072 IPK II DOCUMENT REVISION 1 RELEASE 1000 ...
Page 4: ......
Page 6: ......
Page 50: ...Document Revision 1 Electra Elite IPK II 2 28 Alarm THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 104: ...Document Revision 1 Electra Elite IPK II 2 82 Barge In THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 166: ...Document Revision 1 Electra Elite IPK II 2 144 Callback THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 254: ...Document Revision 1 Electra Elite IPK II 2 232 Conference THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 366: ...Document Revision 1 Electra Elite IPK II 2 344 Door Box THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 370: ...Document Revision 1 Electra Elite IPK II 2 348 Drop Key THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 428: ...Document Revision 1 Electra Elite IPK II 2 406 Flash THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 470: ...Document Revision 1 Electra Elite IPK II 2 448 Hotel Motel THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 482: ...Document Revision 1 Electra Elite IPK II 2 460 Intercom THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 574: ...Document Revision 1 Electra Elite IPK II 2 552 K CCIS T1 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 600: ...Document Revision 1 Electra Elite IPK II 2 578 Memo Dial THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 776: ...Document Revision 1 Electra Elite IPK II 2 754 SLT Adapter THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 872: ...Document Revision 1 Electra Elite IPK II 2 850 Transfer THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 995: ......
Page 996: ...FEATURES AND SPECIFICATIONS MANUAL NEC Unified Solutions Inc Document Revision 1 ...