![MUTOH Falcon II Outdoor Maintenance Manual Download Page 252](http://html1.mh-extra.com/html/mutoh/falcon-ii-outdoor/falcon-ii-outdoor_maintenance-manual_1860155252.webp)
Falcon II Outdoor series printers – Maintenance Manual
252
AP-74065, Rev. 1.0, 21/11/03
Notes :
¾
The adjustment values are as follows.
HIGH level (with media) A/D value
In hexadecimal number : D8 to DF (H)
In decimal number : 216 to 223 (H)
LOW level (without media) A/D value
In hexadecimal number : 30 to 0 (H)
In decimal number : 48 to 0 (H)
(1) HIGH level (with media) adjustment of the A/D value
Step 1 :
Set the standard media.
Step 2 :
Select "Check : Head Lock" in the self-diagnosis menu.
Notes :
¾
Refer to “Self-Diagnosis Function ".
Step 3 :
Release the head lock.
Step 4 :
Check if the installation angle of the P_EDGE sensor is 15°.
Step 5 :
In the inspection menu, select "Check : Check".
Step 6 :
Display "Sensor : PaperEdgeAD".
Step 7 :
Open the front cover.
Step 8 :
Move the carriage so that the dimension between the right edge of the standard media and the cutter is 5 to 10
cm.
1 = Razor Blade
2 = Carriage