Step 5 :
Magnifying by the loupe, move the angle adjustment screw on the head to adjust the head angle until dotted line
on printing A becomes straight.
Step 6 :
If CW is aligned but CCW is not, make adjustments until amount of CW and CCW offset are identical.
1 = Angle adjustment screw
Notes :
¾
For 87-inch specifications, the head 5-A, 5-B, 6-A, 6-B, 7-A, 7-B, 8-A, 8-B are
added.
Step 7 :
Tighten the screw fixing the head stationary plate.
7.7.2. Front and back of head adjustment
Step 1 :
Start the self-diagnostic function.
Notes :
¾