Falcon II Outdoor series printers – Maintenance Manual
208
AP-74065, Rev. 1.0, 21/11/03
5.9.9. General Endurance Menu
This menu performs the general endurance running.
You can operate various driving systems according to your desired settings.
The available settings are shown below.
Setup item
Description
Parameters
Remarks
Operation speed (CW,
CCW)
Sets carriage operation
speed (CW and CCW).
240/300 Unit:
cps
Media feed amount
Set the media feed
amount per cycle
0 to 100
Unit: mm
Number of endurance
running cycles
Set the number of
endurance running
cycles
-1 to 10000
Notes :
¾
If the number of endurance running cycles is set to -1, the units continuously repeat
endurance running until a key input is given from the operation panel.
¾
The maximum counter value for endurance running cycles is 99999999 (up to 8-digit
number). If the number of cycles exceeds the maximum value, the counter is reset
to 0.
* Speed CW *
Speed
240 / 300 + Speed (CW)
240 cps -
↓
ENTER
* Speed CCW *
Speed
240 / 300 + Speed (CCW)
240 cps -
↓
ENTER
* Feed Amount *
0 – 100.0 mm + Media feed amount
0.1 mm -
↓
ENTER
* Life Count *
Count
-1
→
10000 + Number of total endurance running cycles
50
-
↓
ENTER