![MUTOH Falcon II Outdoor Maintenance Manual Download Page 194](http://html1.mh-extra.com/html/mutoh/falcon-ii-outdoor/falcon-ii-outdoor_maintenance-manual_1860155194.webp)
Falcon II Outdoor series printers – Maintenance Manual
194
AP-74065, Rev. 1.0, 21/11/03
(5) Mechanical parameter
Update the mechanical position parameters. The setup items are as follows.
¾
Top
distance
¾
Bottom
distance
¾
Side
margin
¾
P_REAR sensor position
* Mechparm *
Top Length
0 – 40.0 +
5.0 mm -
* Mechparm *
Bottom
0 – 40.0 +
5.0 mm -
* Mechparm *
Side
0 – 20.0 +
5.0 mm -
* Mechparm *
Rear Sensor
0 – 27.0 +
17.0 mm -
↓
ENTER
* Mechparm *
Update
Parameter
↓
ENTER
* Mechparm *
Updating
Parameter
(6) Ink parameter
This updates the ink parameter. The setup items are as follows.
Set: Ink not filled
Reset: Ink filled
Notes :
¾
When "set" has been selected on the ink parameter update menu, the product
implements initial filling operations at the next start up.