Step 14 :
Replace the CR tape power cable.
1 = Tube push plate
2 = Cable clamp
2 = Pipe clamp
3 = Coupling, O-ring, coupling screws
4 = Screws fixing tube push plate (M3x8)
4 = Screws fixing tube cramp (M3x20)
Step 15 :
Reinstall all parts in the opposite order of the removal procedure.
Notes :
¾
The CR tape power cables must be bundled during installation so that they can not
move.
¾
The edge of the tube push plate must be upside when installed.
¾
You should soak the O-ring in cleaning liquid once gain before installing it.