![MUTOH Falcon II Outdoor Maintenance Manual Download Page 246](http://html1.mh-extra.com/html/mutoh/falcon-ii-outdoor/falcon-ii-outdoor_maintenance-manual_1860155246.webp)
Falcon II Outdoor series printers – Maintenance Manual
246
AP-74065, Rev. 1.0, 21/11/03
7.10. CR DECELERATION BELT TENSION ADJUSTMENT
This section explains the procedure for adjusting the tension of the CR deceleration belt.
When removing/installing the CR deceleration belt, such as when removing the CR motor, adjust the tension of the CR
deceleration belt.
7.10.1. Tools required for work
The following tools are required to adjust the tension of the CR deceleration belt.
¾
Tension gauge: max. 50 N (5 kgf)
Notes :
¾
Refer to “Jig and Tool List ".
7.10.2. Adjustment Procedure
Use the following procedure to adjust the tension of the CR deceleration belt.
Step 1 :
Loosen the 4 hexagon socket head cap screws fixing the CR motor installation board.
1 = CR motor installation board
2 = Hexagon socket head cap screw
3 = CR motor assembly
4 = Tension gauge
Step 2 :
Install the tension gauge on the PF motor installation board.
Step 3 :
Pull the tension gauge in the direction of the arrow shown on the figure above.
Notes :
¾
The regulated value of the tension for the CR deceleration belt is 34.32 N
±
10 %
(3,5 kgf
±
10 %).
Step 4 :