![MUTOH Falcon II Outdoor Maintenance Manual Download Page 198](http://html1.mh-extra.com/html/mutoh/falcon-ii-outdoor/falcon-ii-outdoor_maintenance-manual_1860155198.webp)
Falcon II Outdoor series printers – Maintenance Manual
198
AP-74065, Rev. 1.0, 21/11/03
5.9.1. CR Motor Endurance Menu
This menu performs endurance running for the CR motor.
You can perform carriage stroke according to your desired setting. The available settings are shown below.
Setup item
Description
Parameters
Remarks
Operation speed (CW,
CCW)
Sets carriage operation
speed (CW and CCW).
240, 300
Unit: cps
Number of endurance
running cycles
Set the number of
endurance running
cycles
-1 to 10000
Notes :
¾
If the number of endurance running cycles has been set to -1, the units continuously
repeat endurance running until a key input is given from the operation panel.
¾
The maximum counter value for endurance running cycles is 99999999 (up to 8-digit
number). If the number of cycles exceeds the maximum value, the counter is reset
to 0.
* Speed CW *
Speed
240 / 300 + Speed (CW)
240 cps -
↓
ENTER
* Speed CCW *
Speed
240 / 300 + Speed (CCW)
240 cps -
↓
ENTER
* Aging Count *
Count
-1
→
10000 + Number of endurance running cycles
50
-
↓
ENTER
* CR Motor *
Count
5 Perform endurance running
↓
ENTER
* CR Motor *
End
50