![MUTOH Falcon II Outdoor Maintenance Manual Download Page 109](http://html1.mh-extra.com/html/mutoh/falcon-ii-outdoor/falcon-ii-outdoor_maintenance-manual_1860155109.webp)
Falcon II Outdoor series printers – Maintenance Manual
109
AP-74065, Rev. 1.0, 21/11/03
1 = Head tape power cable
2 = Damper assembly
3 = Head stationary plate / head spacer
4 = Step-bore screw
5 = Screws (M2.6x5) fixing the head stationary plate
6 = Print head assembly
Step 5 :
Remove the damper assembly from the print head assembly.
Step 6 :
Remove the screw and step-bore screw fixing the head stationary plate.
Step 7 :
Remove the rotation adjustment spring under the head with small flat-head driver or another tool.
Step 8 :
Replace the print head assembly.
Step 9 :
Reinstall all parts in the opposite order of the removal procedure.
Notes :
¾
Place the removed damper assembly facing upward and fix with tape or place it in a
container to prevent the ink from leaking. Ink adhesion on board may cause faulty
print head.
¾
Align the head tape power cables one by one to each head and paste together with
double-faced tape.
¾
Make sure that the head does not float when installing the head.
A : Insert the concave portion of the head base in the rear of the cursor convex portion of the cursor.
B : Insert the rotation adjustment spring into the convex portion of the head base on the right front.
Step 10 :
Perform head precision adjustment according to "Head precision adjustment".