75
CHAPTER 3 SPECIFICATIONS
3
3.
7
List
s of
R
e
mot
e
B
u
ffer
Mem
o
ry
Areas
*1
The default value depends on the mode used. For details on the default value, refer to the following.
*2
This column indicates whether data can be read from or written to the remote buffer memory area through sequence
programs.
R: Reading enabled
W: Writing enabled
*3
This column indicates whether the setting in the remote buffer memory area is automatically changed when the input
range is changed. For details, refer to the following.
*4
This column indicates whether data can be written to the non-volatile memory by turning off and on Set value backup
instruction (RY15). For details, refer to the following.
*5
This column indicates whether or not the setting can be changed by turning off and on During operation setting change
instruction (RY10). For details, refer to the following.
*6
This column indicates whether or not the setting can be changed by turning off and on Initial data setting request flag
(RY9) when all channels stop. For details, refer to the following.
*7
(TT) represents NZ2GF2B-60TCTT4. (RT) represents NZ2GF2B-60TCRT4.
*8
By using the setting change rate limiter, whether to set temperature rise/temperature drop in a batch or individually can
be selected. In the batch setting, the target of setting change rate limiter is only this area. In the individual setting, this
area is the setting target for the temperature rise. For details, refer to the following.
*9
Available only under the mix control (expanded mode). With other models, this area is handled as a system area.
*10
Available only under the heating-cooling control (expanded mode). With other models, this area is handled as a system
area.
*11
Available only under the mix control (normal mode). With other models, this area is handled as a system area.
*12
Available only under the heating-cooling control (normal mode). With other models, this area is handled as a system
area.
*13
By using the setting change rate limiter, whether to set temperature rise/temperature drop in a batch or individually can
be selected. In the batch setting, this area is handled as a system area. In the individual setting, this area is the setting
target for the temperature drop. For details, refer to the following.
*14
Available only when the NZ2GF2B-60TCTT4 is used. With other models, this area is handled as a system area.
732 (2DCH)
CH4
Simultaneous
temperature
rise group
setting
System area
Simultaneous
temperature
rise group
setting
0
R/W
733 (2DDH)
CH4
Simultaneous
temperature
rise gradient
data
System area
Simultaneous
temperature
rise gradient
data
0
R/W
734 (2DEH)
CH4
Simultaneous
temperature
rise dead time
System area
Simultaneous
temperature
rise dead time
0
R/W
735 (2DFH)
CH4
Simultaneous
temperature
rise AT mode
selection
System area
Simultaneous
temperature
rise AT mode
selection
0
R/W
736 to
1279(2E0H
to 4FFH)
System area
System area
System area
Address
(decimal
(hexa-
decimal))
Target
channel
Setting contents
Default
value
*1
Read/
Write
*2
Auto-
matic
setting
*3
Non-
volatile
memory
write
avail-
ability
*4
Change
of
setting
during
opera-
tion
*5
Change
of setting
when all
channels
stop
*6
Reference
Standard
control
Heating-
cooling
control
Mix control
Summary of Contents for NZ2GF2B-60TCRT4
Page 2: ......
Page 86: ...84 Memo ...
Page 268: ...266 Memo ...
Page 377: ...375 APPENDICES A Appendix 6 External Dimensions Memo ...
Page 383: ...I 4 4 7 8 381 Memo ...
Page 387: ......