116
*1
For the NZ2GF2B-60TCTT4, "Setting Range" is already set to -2000 to 32000, which is the lower limit value of the
setting range for Input range (Input range: 7, 10, 20, 29, 41) and the upper limit value (Input range: 205) (For the
NZ2GF2B-60TCRT4, the lower limit value is -3000). When actually set the values, enter the values within the setting
range for Input range.
*2
"Setting Range" is already set to -32000 to 32000, which is the lower limit value of the setting range (Input range: 205)
and the upper limit value (Input range: 205). When actually set the values, enter the values within the setting range of
the set alert mode.
*3
"Setting Range" is already set to -32000 to 32000, which is the full scale lower limit value for Input range (Input range:
205) and the full scale upper limit value (Input range: 205). When actually set the values, enter the values within the full
scale range for Input range.
(d) Setting items of when "Param write (Mix control (Normal))" or "Param write (Mix
control (Extension))" is set
CH
Auto tuning setting
CH
Auto tuning mode selection
CH
AT bias
Setting item
Reference
CH
Basic setting
CH
Input range
CH
Target value_SV_setting
CH
PID Constant setting
CH
Proportion belt_P_setting_CH
Heating proportion belt
CH
Integration time_I_setting
CH
Differentiation time_D_setting
CH
Limiter setting 1
CH
Heating upper limit output limiter
CH
Limiter setting 2
CH
Output change amount limiter
CH
Setting change rate limiter or CH
Setting change rate
limiter_temperature rise
CH
Setting change rate limiter unit time setting
CH
Upper limit setting limiter
CH
Lower limit setting limiter
CH
Limiter setting
CH
Upper limit output limiter
CH
Lower limit output limiter
CH
Output change amount limiter
CH
Setting change rate limiter or CH
Setting change rate
limiter_temperature rise
CH
Setting change rate limiter unit time setting
CH
Upper limit setting limiter
CH
Lower limit setting limiter
CH
Control output cycle setting_CH
Heating control output cycle setting
CH
Primary delay digital filter setting
CH
Moving averaging count setting
CH
Control response parameter
CH
Differentiation operation selection
CH
Adjustment sensitivity_non-inductive belt_setting
CH
Forward action_Reverse action setting
CH
Loop disconnection detection
CH
Loop disconnection detection judgment time
CH
Loop disconnection detection dead band
CH
Stop mode setting
CH
Automatic backup setting after auto tuning of PID constants
CH
Temperature conversion setting
CH
Heating/Cooling_mix control setting
CH
Cooling proportion belt_Pc_setting
CH
Cooling upper limit output limiter
CH
Cooling control output cycle setting
CH
Overlap_dead band setting
Setting item
Reference