46
Do not use any "Use prohibited" remote I/O signals. If any of the signals are used, correct operation of the module cannot be
guaranteed.
3.6
Lists of Remote Register Areas
This section lists remote register areas for a master/local module. In the example of the remote register assignment
described in this section, the remote registers of the main module are assigned to the remote registers of RWr0 to
RWr1F and RWw0 to RWw1F.
Remote register (RWr) is the information input from the temperature control module to the master/local module.
Remote register (RWw) is the information output from the master/local module to the temperature control module.
For details on the remote register, refer to the following.
(1) List of remote register (RWr) areas
Remote register (RWr)
Signal direction: Temperature control module
Master/local module
Device number
Temperature input
Standard control
Heating-cooling control
Mix control
RWr0
Latest error code
Latest error code
Latest error code
Latest error code
RWr1
Error occurrence address
Error occurrence address
Error occurrence address
Error occurrence address
RWr2
Latest warning code
Latest warning code
Latest warning code
Latest warning code
RWr3
Use prohibited
CH1 to CH4 AT simultaneous
temperature rise parameter
calculation flag
Use prohibited
CH1 to CH4 AT simultaneous
temperature rise parameter
calculation flag
RWr4
CH1 Alert definition
CH1 Alert definition
CH1 Alert definition
CH1 Alert definition
RWr5
CH2 Alert definition
CH2 Alert definition
CH2 Alert definition
CH2 Alert definition
RWr6
CH3 Alert definition
CH3 Alert definition
CH3 Alert definition
CH3 Alert definition
RWr7
CH4 Alert definition
CH4 Alert definition
CH4 Alert definition
CH4 Alert definition
RWr8
CH1 Temperature process
value (PV) or CH1 Process
value (PV) scaling value
CH1 Temperature process
value (PV) or CH1 Process
value (PV) scaling value
CH1 Temperature process
value (PV) or CH1 Process
value (PV) scaling value
CH1 Temperature process
value (PV) or CH1 Process
value (PV) scaling value
RWr9
CH2 Temperature process
value (PV) or CH2 Process
value (PV) scaling value
CH2 Temperature process
value (PV) or CH2 Process
value (PV) scaling value
CH2 Temperature process
value (PV) or CH2 Process
value (PV) scaling value
CH2 Temperature process
value (PV) or CH2 Process
value (PV) scaling value
RWrA
CH3 Temperature process
value (PV) or CH3 Process
value (PV) scaling value
CH3 Temperature process
value (PV) or CH3 Process
value (PV) scaling value
CH3 Temperature process
value (PV) or CH3 Process
value (PV) scaling value
CH3 Temperature process
value (PV) or CH3 Process
value (PV) scaling value
RWrB
CH4 Temperature process
value (PV) or CH4 Process
value (PV) scaling value
CH4 Temperature process
value (PV) or CH4 Process
value (PV) scaling value
CH4 Temperature process
value (PV) or CH4 Process
value (PV) scaling value
CH4 Temperature process
value (PV) or CH4 Process
value (PV) scaling value
RWrC
Use prohibited
CH1 Set value (SV) monitor
CH1 Set value (SV) monitor
CH1 Set value (SV) monitor
RWrD
Use prohibited
CH2 Set value (SV) monitor
CH2 Set value (SV) monitor
CH2 Set value (SV) monitor
RWrE
Use prohibited
CH3 Set value (SV) monitor
CH3 Set value (SV) monitor
CH3 Set value (SV) monitor
RWrF
Use prohibited
CH4 Set value (SV) monitor
CH4 Set value (SV) monitor
CH4 Set value (SV) monitor
RWr10
Use prohibited
CH1 Manipulated value (MV)
CH1 Manipulated value for
heating (MVh)
CH1 Manipulated value for
heating (MVh)
RWr11
Use prohibited
CH2 Manipulated value (MV)
CH2 Manipulated value for
heating (MVh)
CH2 Manipulated value for
heating (MVh)
RWr12
Use prohibited
CH3 Manipulated value (MV)
CH3 Manipulated value for
heating (MVh)
CH3 Manipulated value (MV)