Quadrus EZ Reader User’s Manual
4-13
Symbologies
Fixed Symbol Length Status (BC412)
Fixed Symbol Length (BC412)
Definition:
When enabled the reader will check the symbol length against the symbol
length field. If disabled any length would be considered a valid symbol.
Serial Cmd:
<
K481,
status,check digit output,
fixed symbol length status
,fixed symbol
length>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Usage:
Fixed Symbol Length helps prevent truncations and increases data integrity
by ensuring that only one symbol length will be accepted.
Definition:
Specifies the exact number of characters that the reader will recognize (this
does not include start and stop and check digit characters). The reader
ignores any symbology not having the specified length.
Serial Cmd:
<
K481,
status,check digit output,fixed symbol length status,
fixed symbol
length
>
Default:
10
Options:
1 to 64