Quadrus EZ Reader User’s Manual
9-3
Camera Setup
Video
In the Camera menu you can locate and capture images just as you did in the EZ Mode
when first starting ESP.
Locate
Turns on the blue X-pattern to help you center the symbol in the field of view.
Calibrate
If you haven’t already calibrated the symbol,
1. Click the
Locate
button and center the X pattern over the symbol.
2. Click the
Calibrate
button to optimize read rate.
The reader will search through various IP (image processing) settings and match
them with the highest read rates.
A successful calibration will display the calibrated symbol image a message, “Calibrated
successfully”.
3. Click
Close
on the Calibration dialog.
After a short wait, the symbol’s data and related features will be presented under the
“Symbol Information” box below the image display window, as shown in the following
example:
Calibrate by Serial Command
Send
<op,6,1>
to begin calibration. Send
<op,6,0>
to terminate calibration.
Summary of Contents for Quadrus EZ
Page 1: ...Quadrus EZ Reader User s Manual P N 83 006700 Rev T...
Page 116: ...4 32 Quadrus EZ Reader User s Manual Background Color...
Page 172: ...5 56 Quadrus EZ Reader User s Manual Output 3 Parameters...
Page 186: ...6 14 Quadrus EZ Reader User s Manual Static Symbol Quality Outputs...
Page 208: ...8 8 Quadrus EZ Reader User s Manual Service Message...
Page 232: ...9 24 Quadrus EZ Reader User s Manual Other Camera Parameters...
Page 252: ...11 6 Quadrus EZ Reader User s Manual Terminal Window Menus...
Page 294: ...14 14 Quadrus EZ Reader User s Manual Ordered Output Filter...
Page 346: ...A 42 Quadrus EZ Reader User s Manual Glossary of Terms...