9-18
Quadrus EZ Reader User’s Manual
Thresholding
Thresholding
Threshold Mode
Threshold Value
Usage:
Fixed works better when decode time must be as short as possible and the
reflectance and illumination of the symbol area is uniform and unchanging.
Otherwise Adaptive is the preferred mode.
Definition:
This value switches the image processing threshold mode between the
Adaptive and Fixed modes.
An adaptive routine sets the light/dark threshold from data acquired from
the current read. A fixed mode applies the same gray scale threshold value
to each and every symbol.
Generally, Adaptive gives better results than Fixed.
Unlike Adaptive, Fixed applies the same value consistently to each and
every symbol.
Serial Cmd:
<
K512,threshold mode
,threshold value>
Default:
Adaptive
Options:
0 = Adaptive
1 = Fixed
Usage:
A higher value will increase the threshold for distinguishing between light
and dark elements.
Definition:
Determines how the reader will distinguish light from dark pixels.
This value is used for the Fixed Mode only. When the Adaptive Mode is set,
this value is ignored.
Serial Cmd:
<
K512,
threshold mode,
threshold value
>
Default:
128
Options:
0 to 255
Summary of Contents for Quadrus EZ
Page 1: ...Quadrus EZ Reader User s Manual P N 83 006700 Rev T...
Page 116: ...4 32 Quadrus EZ Reader User s Manual Background Color...
Page 172: ...5 56 Quadrus EZ Reader User s Manual Output 3 Parameters...
Page 186: ...6 14 Quadrus EZ Reader User s Manual Static Symbol Quality Outputs...
Page 208: ...8 8 Quadrus EZ Reader User s Manual Service Message...
Page 232: ...9 24 Quadrus EZ Reader User s Manual Other Camera Parameters...
Page 252: ...11 6 Quadrus EZ Reader User s Manual Terminal Window Menus...
Page 294: ...14 14 Quadrus EZ Reader User s Manual Ordered Output Filter...
Page 346: ...A 42 Quadrus EZ Reader User s Manual Glossary of Terms...