Quadrus EZ Reader User’s Manual
7-11
Matchcode
Sequence Step
As an example of Sequence Step, if Sequence Step is set to 3 and Sequential Matching
is set to Increment.
Usage:
Useful in applications in which it is desirable to count by intervals other than 1.
Definition:
Sequencing in Matchcode operations can occur in steps from 1 to 32,768.
Sequencing performs like a mechanical counter by displaying positive inte-
gers and a specific number of digits after roll-overs. For example, 000 – 3 =
997 (not –3) and 999 + 3 = 002 (not 1002).
Serial Cmd:
<
K228,
sequence step>
Default:
1
Options:
1 to 32,768
Master symbol
Decoded
symbol
Master symbol after decode
003
001
003
003
002
003
003
003
006
006
004
006
006
005
006
006
006
009