4-20
Quadrus EZ Reader User’s Manual
Pharmacode
Pharmacode
Fixed Symbol Length Status (Pharmacode)
Fixed Symbol Length (Pharmacode)
Minimum Number of Bars (Pharmacode)
Usage:
Used mostly with packaging for the pharmaceuticals industry.
Definition:
Encodes up to five different numbers, each with its own color which may be
entered in decimal or “binary” format with a 1 represented by a thick bar and
a 0 represented by a thin bar. Bar width is independent of height.
In decimal format, each part can be up to 999999.
In binary format, each input have up to 19 ones and zeros.
Serial Cmd:
<
K477,status
,fixed symbol length status,fixed symbol length,min. no. of
bars,bar width status,direction,fixed threshold value>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Definition:
When enabled, the reader will check the symbol length against the symbol
length field. If disabled, any length would be considered a valid symbol.
Serial Cmd:
<
K477,
status,
fixed symbol length status
,fixed symbol length,min. no. of
bars,bar width status,direction,fixed threshold value>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Definition:
This specifies the exact number of characters that the reader will recognize
(this does not include start and stop and check digit characters). The reader
ignores any symbology not having the specified length.
Serial Cmd:
<
K477,
status,fixed symbol length status,
fixed symbol length
,min. no. of
bars,bar width status,direction,fixed threshold value>
Default:
10
Options:
4 to 16
Definition:
Sets the minimum number of bars that a pharmacode symbol must have to
be considered as a valid symbol.
Serial Cmd:
<
K477,
status,fixed symbol length status,fixed symbol length,
min. no. of
bars
,bar width status,direction,fixed threshold value>
Default:
4
Options:
4 to 16
Summary of Contents for Quadrus EZ
Page 1: ...Quadrus EZ Reader User s Manual P N 83 006700 Rev T...
Page 116: ...4 32 Quadrus EZ Reader User s Manual Background Color...
Page 172: ...5 56 Quadrus EZ Reader User s Manual Output 3 Parameters...
Page 186: ...6 14 Quadrus EZ Reader User s Manual Static Symbol Quality Outputs...
Page 208: ...8 8 Quadrus EZ Reader User s Manual Service Message...
Page 232: ...9 24 Quadrus EZ Reader User s Manual Other Camera Parameters...
Page 252: ...11 6 Quadrus EZ Reader User s Manual Terminal Window Menus...
Page 294: ...14 14 Quadrus EZ Reader User s Manual Ordered Output Filter...
Page 346: ...A 42 Quadrus EZ Reader User s Manual Glossary of Terms...