Quadrus EZ Reader User’s Manual
3-21
Read Cycle
Triggered Capture
Notes on Triggered Capture Mode:
1. Trigger Mode <K200> must be set to Edge, Serial, or Serial & Edge. If set to
Level, Triggered Capture Mode will operate the same as Timed Rapid Capture
mode.
2. For End of Read Cycle settings <K220>:
a) If set to Timeout or New Trigger & Timeout and a timeout occurs before number
of capture have been met, it will abort the read cycle and disregard the remaining
number of triggers.
b)
If set to New Trigger, the reader remains in the read cycle until the number of
captures is satisfied and an additional trigger is received indicating both the end
of the read cycle and the start and first capture of the next read cycle.
Triggered Captures, Typical
Usage:
Useful in applications where delays between captures can be controlled by
triggers rather than preset time delays.
Definition:
When enabled the reader will stay in the read cycle until either the user-
defined number of captures has been met or, if configured, a timeout
occurs.
Processing
Read cycle
ends on New
Trigger or Tim-
eout, as config-
ured.
Captures on every trigger
Capture
First trigger
starts the read
cycle
Summary of Contents for Quadrus EZ
Page 1: ...Quadrus EZ Reader User s Manual P N 83 006700 Rev T...
Page 116: ...4 32 Quadrus EZ Reader User s Manual Background Color...
Page 172: ...5 56 Quadrus EZ Reader User s Manual Output 3 Parameters...
Page 186: ...6 14 Quadrus EZ Reader User s Manual Static Symbol Quality Outputs...
Page 208: ...8 8 Quadrus EZ Reader User s Manual Service Message...
Page 232: ...9 24 Quadrus EZ Reader User s Manual Other Camera Parameters...
Page 252: ...11 6 Quadrus EZ Reader User s Manual Terminal Window Menus...
Page 294: ...14 14 Quadrus EZ Reader User s Manual Ordered Output Filter...
Page 346: ...A 42 Quadrus EZ Reader User s Manual Glossary of Terms...