Quadrus EZ Reader User’s Manual
8-3
Diagnostics
Counts (Read Only)
Counts for Power-on/Reset/Saves are stored in the reader and can be displayed at any
time in response to serial commands listed here, in the embedded Diagnostic menu, or in
ESP by requesting reader settings. If you did not choose to receive reader settings upon
connection in ESP, you can right-click anywhere in the Diagnostic window and select
Receive Reader Settings
.
Power-on
Resets
Power-on Saves
Custom Default Saves
Definition:
Displays a count of the number of times power to the reader is recycled.
Serial Cmd:
<
K406,power-on
,resets,power-on saves,customer default saves>
Definition:
Displays a count of the number of times the reader is reset.
Serial Cmd:
<
K406,
power-on,
resets
,power-on saves,customer default saves>
Definition:
Displays a count of the number of power-on saves
<Z>
command.
Serial Cmd:
<
K406,
power-on,resets,
power-on saves
,customer default saves>
Definition:
Displays a count of the number of power-on saves (customer defaults) to
flash memory (
<Zc>
command)
Serial Cmd:
<
K406,
power-on,resets,power-on saves,
customer default saves
>
Summary of Contents for Quadrus EZ
Page 1: ...Quadrus EZ Reader User s Manual P N 83 006700 Rev T...
Page 116: ...4 32 Quadrus EZ Reader User s Manual Background Color...
Page 172: ...5 56 Quadrus EZ Reader User s Manual Output 3 Parameters...
Page 186: ...6 14 Quadrus EZ Reader User s Manual Static Symbol Quality Outputs...
Page 208: ...8 8 Quadrus EZ Reader User s Manual Service Message...
Page 232: ...9 24 Quadrus EZ Reader User s Manual Other Camera Parameters...
Page 252: ...11 6 Quadrus EZ Reader User s Manual Terminal Window Menus...
Page 294: ...14 14 Quadrus EZ Reader User s Manual Ordered Output Filter...
Page 346: ...A 42 Quadrus EZ Reader User s Manual Glossary of Terms...