4-10
Quadrus EZ Reader User’s Manual
Code 39
Full ASCII Set (Code 39)
Usage:
Must be enabled when reading characters outside the standard character
set (0-9, A-Z, etc.)
User must know in advance whether or not to use Full ASCII Set option.
Since Full ASCII Set requires two code words to encode one character, it is
less efficient.
Definition:
Standard Code 39 encodes 43 characters; zero through nine, capital “A”
through capital “Z”, minus symbol, plus symbol, forward slash, space, decimal
point, dollar sign and percent symbol. When Full ASCII Set is enabled, the
reader can read the full ASCII character set, from 0 to 255.
Serial Cmd:
<
K470,
status,check digit status,check digit output,large intercharacter
gap,fixed symbol length status,fixed symbol length,
full ASCII set
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Summary of Contents for Quadrus EZ