Motor A5 Submenu
75
Parameter
[
Alphanumeric]
Description
Units
Range
Default
Hidden
Item
Run
lockout
ENGLISH
(U3)
METRIC
(U3)
Rated Mtr
Pwr
[A502]
(Rated Motor Power)
This parameter sets the rated power in
horsepower (HP) or kilowatts (kW) of the
motor. Note: value should be obtained
from the motor nameplate
HP
1.0
– 500.0
0.0
N
Y
kW
0.75
– 300.00
0.00
Rated Mtr
Volts
[A503]
(Rated Motor Voltage)
This parameter sets the rated motor
voltage. Note: value should be obtained
from the motor nameplate
Volts
85.0
– 575.0
0.0
N
Y
Rated Excit
Freq
i,
iii
[A504]
(Rated Motor Excitation Frequency
i,
iii
)
This parameter sets the excitation
frequency of the motor. Note: value
should be obtained from the motor
nameplate
Hz
i,
iii
5.0
– 400.0
i,
iii
0.0
i,
iii
N
i,
iii
Y
i,
iii
Rated
Motor Curr
[A505]
(Rated Motor Amps) This parameter sets
the rated motor current. Note: value
should be obtained from the motor
nameplate.
Amps
1.0
– 800.0
0.0
N
Y
Motor
Poles
[A506]
(Motor Poles) This parameter sets the
number of poles in the motor.
NOTE: This must be an even number or
a Setup Fault #3 will occur. Note: value
should be obtained from the motor
nameplate.
none
2
– 128
4
N
Y
Rated Mtr
Speed
[A507]
(Rated Motor Speed)
This parameter sets the rated rpm of the
motor (nameplate speed). NOTE: This is
a function of the motor only and does not
need to be the same as the CONTRACT
MTR SPD (A1) parameter setting. Note:
value should be obtained from the motor
nameplate.
Rated Mtr Speed is defined
as the synchronous speed minus the slip.
At times, the motor manufacturer will
place the synchronous speed on the data
nameplate. The Adaptive Tune
procedure on page 152 calculates the
amount of slip of the motor.
Poles
of
#
frequency
excitation
rated
120
motor
of
speed
s
synchronou
RPM
1.0
– 3000.0
0.0
N
Y
% No Load
Current
i,
iii
[A508]
(Percent No Load Current
i,
iii
)
This parameter sets the percent no load
current of the motor. This parameter sets
the window (
25%) around which the
adaptive tune can adjust the motor’s
percent no load current. Units in percent
of current.
For more information on the
adaptive tune, see Adaptive Tune on
page
%
i,
iii
10.0
– 80.0
i,
iii
per MOTOR ID
i,
iii
N
i,
iii
N
i,
iii
i
Parameter accessible through
CLOSED LOOP (U9)
Operation
ii
Parameter accessibly through
PM (U9)
Operation
iii
Parameter accessible through
OPEN LOOP(U9)
Operation