Multistep Ref A3 Submenu
66
Parameter
[Alphanumeric]
Description
Units
Range
Default
Hidden
Item
Run
lockout
i
V1
ii
[A318]
Speed Reference 1
ft/min
-3000.0
– +3000.0
0.0
N
Y
m/sec
-16.000
– +16.000
0.000
V2
ii
[A319]
Speed Reference 2
ft/min
-3000.0
– +3000.0
0.0
N
Y
m/sec
-16.000
– +16.000
0.000
V3
ii
[A320]
Speed Reference 3
ft/min
-3000.0
– +3000.0
0.0
N
Y
m/sec
-16.000
– +16.000
0.000
V4
ii
[A321]
Speed Reference 4
ft/min
-3000.0
– +3000.0
0.0
N
Y
m/sec
-16.000
– +16.000
0.000
VI
ii
[A322]
Inspection Speed
ft/min
-3000.0
– +3000.0
0.0
N
Y
m/sec
-16.000
– +16.000
0.000
Unlock Spd Level
ii
[A323]
When the elevator is
traveling at or below this
speed the drive will
advise the control
system serially (used for
pre-opening of doors)
ft/min
0.00
– 600.0
8.0
N
Y
m/sec
0.00
– 300.0
0.800
Lvling Spd Level
ii
[A324]
When the elevator is
traveling at or below this
speed the drive will
advise the control
system serially (used by
the control system when
releveling with the doors
open)
ft/min
0.00
– 600.0
3.0
N
Y
m/sec
0.00
– 300.0
0.300
Border Spd Level
ii
[A325]
When the elevator is
traveling at or below this
speed the drive will
advise the control
system serially (used for
speed monitoring on
approaching terminal
floors)
ft/min
0.00
– 600.0
10.0
N
Y
m/sec
0.00
– 300.0
1.000
Re-level Spd Hi
ii
[A326]
For Magnetek personnel
– Used when optimizing
final stopping sequence
(DCP4 only)
ft/min
0.00
– 60.0
10.00
N
Y
m/sec
0.00
– 0.30
0.050
Re-level Spd Low
ii
[A327]
For Magnetek personnel
– Used when optimizing
final stopping sequence
(DCP4 only)
ft/min
0.00
– 60.0
01.00
N
Y
m/sec
0.00
– 0.30
0.005
Table 11: Multistep Ref A3 Submenu
i
Parameter only accessible when SERIAL MODE (C1) is set to None, Mode1, Mode2 or Mode3
ii
Parameter only accessible when SERIAL MODE (C1) is set to DCP3 or DCP4