![background image](http://html1.mh-extra.com/html/magnetek/hpv-900-series-2/hpv-900-series-2_technical-manual_3606659220.webp)
APPENDIX
– Relay Specifications
198
Appendix
Relay Specifications
RELAY 1 & 2
Contact Data
Load
Resistive load
(p.f. = 1)
N.O. Contact
N.C. Contact
Rated Load
5A at 277VAC
10A at 125VAC
5A at 30VDC
3A at 277VAC
3A at 30VDC
Carry Current
10A
3A
Max. operating voltage
277VAC, 30VDC
Max. operating current
10A
3A
Max. operating capacity
1,385VA, 150W
831VA, 90W
Min recommended
contact load
100mA, 5Vdc
Contact material
AgSnO2
Manuafacturer
Tyco, PCH-124D2H
Operating Time
Figure 62: Operate Time
Coil Temperature Rise
Figure 63: Coil
Temperature
Life Expectancy
Figure 64: Relay Life