User Switches C1 Submenu
89
Parameter
[Alphanumeric]
Description
Choices
Default
Hidden
item
Run
lockout
ENGLISH
(U3)
METRIC
(U3)
Dir Confirm
[C136]
(Direction Confirm)
When enabled, the function allows
confirmation of the polarity of the initial
analog speed command via the Run Up or
Run Down logic input commands.
If the Run Up logic input is selected
and true with the polarity of the
analog signal positive, then the
analog speed command is accepted
unchanged.
If the logic input Run Down logic
input is selected and true with the
polarity of the analog speed
command negative, the analog
speed command is accepted
unchanged.
If however, the logic input Run Up is
true and the polarity is negative or
the logic input Run Down is true and
the polarity is positive, then the
speed command is held at zero.
enabled
[1]
disabled
[0]
DISABLED
Y
Y
Mains Dip
Ena
[C137]
(Mains Dip Enable)
When enabled, the function limit the
speed (to the percentage of contract
speed defined by the MAINS DIP SPEED
parameter).
Low Mains: defined by UV alarm level
EXT TB: Logic Input
Serial: Serial Link
Disable
[0]
Low Mains
[1]
Ext TB
[2]
Serial
[3]
DISABLE
Y
Y