Display D0 Menu
110
D1 8:55
Start Logic
000-0000-0000-0000
READY
RUN
USER
FAULT
TORQUE
LIMIT
SUB MENU
DATA ENTRY
Bit 0
Bit 14
Parameter
[Alphanumeric]
Description
Units
Hidden
item
Start Logic
i,ii
[D111]
(Start Logic Status
i
,ii
) - This display shows the condition of certain
starting logic bits. (1=true 0=false)
Bit Name Description/Reason
0 RUN_BIT Software recognized input run command
1
BRAKE_RUN_BIT Run command after internal brake
control delay
2
DRIVE_RUN)BIT Drive Run command after all drop out
delays
3
RDY_FOR_RUN_BIT Drive is ready for run command, no
faults present
4
CLOSE_CONTACTOR_BIT Indicates the drive is enabled,
run command has been received, the software is initialized
and no faults are present
5
CNTCT_CONFIRM_BIT Software indication that it has
received the confirmation that the contactor has closed
6
RAMP_DWN_EN_BIT Bit is true after a torque ramp down
stop has been initiated by either a logic input, the serial
channel, or internally by the drive.
7
RUN_CONFIRM_BIT When 1, no faults are present, drive
has been commanded to run, the contactor has closed and
the IGBTs are firing
1=true
0=false
i,ii
N
i
,ii
i
Parameter accessible through
CLOSED LOOP (U9)
Operation
ii
Parameter accessibly through
PM (U9)
Operation
iii
Parameter accessible through
OPEN LOOP(U9)
Operation