Multistep Ref A3 Submenu
65
Parameter
[Alphanumeric]
Description
Units
Range
Default
Hidden
Item
Run
lockout
Speed Command 1
i
[A301]
Multi-step speed
command #1
ft/min
-3000.0
– +3000.0
0.0
N
Y
m/sec
-16.000
– +16.000
0.000
Speed Command 2
i
[A302]
Multi-step speed
command #2
ft/min
-3000.0
– +3000.0
0.0
N
Y
m/sec
-16.000
– +16.000
0.000
Speed Command 3
i
[A303]
Multi-step speed
command #3
ft/min
-3000.0
– +3000.0
0.0
N
Y
m/sec
-16.000
– +16.000
0.000
Speed Command 4
i
[A304]
Multi-step speed
command #4
ft/min
-3000.0
– +3000.0
0.0
N
Y
m/sec
-16.000
– +16.000
0.000
Speed Command 5
i
[A305]
Multi-step speed
command #5
ft/min
-3000.0
– +3000.0
0.0
N
Y
m/sec
-16.000
– +16.000
0.000
Speed Command 6
i
[A306]
Multi-step speed
command #6
ft/min
-3000.0
– +3000.0
0.0
N
Y
m/sec
-16.000
– +16.000
0.000
Speed Command 7
i
[A307]
Multi-step speed
command #7
ft/min
-3000.0
– +3000.0
0.0
N
Y
m/sec
-16.000
– +16.000
0.000
Speed Command 8
i
[A308]
Multi-step speed
command #8
ft/min
-3000.0
– +3000.0
0.0
N
Y
m/sec
-16.000
– +16.000
0.000
Speed Command 9
i
[A309]
Multi-step speed
command #9
ft/min
-3000.0
– +3000.0
0.0
N
Y
m/sec
-16.000
– +16.000
0.000
Speed Command 10
i
[A310]
Multi-step speed
command #10
ft/min
-3000.0
– +3000.0
0.0
N
Y
m/sec
-16.000
– +16.000
0.000
Speed Command 11
i
[A311]
Multi-step speed
command #11
ft/min
-3000.0
– +3000.0
0.0
N
Y
m/sec
-16.000
– +16.000
0.000
Speed Command 12
i
[A312]
Multi-step speed
command #12
ft/min
-3000.0
– +3000.0
0.0
N
Y
m/sec
-16.000
– +16.000
0.000
Speed Command 13
i
[A313]
Multi-step speed
command #13
ft/min
-3000.0
– +3000.0
0.0
N
Y
m/sec
-16.000
– +16.000
0.000
Speed Command 14
i
[A314]
Multi-step speed
command #14
ft/min
-3000.0
– +3000.0
0.0
N
Y
m/sec
-16.000
– +16.000
0.000
Speed Command 15
i
[A315]
Multi-step speed
command #15
ft/min
-3000.0
– +3000.0
0.0
N
Y
m/sec
-16.000
– +16.000
0.000
V0
ii
[A316]
Leveling Speed
ft/min
-3000.0
– +3000.0
0.0
N
Y
m/sec
-16.000
– +16.000
0.000
VN
ii
[A317]
Re-Leveling Speed
ft/min
-3000.0
– +3000.0
0.0
N
Y
m/sec
-16.000
– +16.000
0.000
i
Parameter only accessible when SERIAL MODE (C1) is set to None, Mode1, Mode2 or Mode3
ii
Parameter only accessible when SERIAL MODE (C1) is set to DCP3 or DCP4